Systems
- We select the appropriate combination of pumps, filters and dosing equipment for each site.
- We have special expertise with chilled and hot water systems.
- Poor quality water supplies coming from dams or rivers can be treated to potable water standard.
Chemicals
- Disinfection is necessary to extend shelf life and maintain water quality.
- Ym-Fab have a range of chemicals to suit every situation in pre harvest, post harvest and semi processed fruit and vegetable production.
- Effective ORP control requires a steady pH in the wash water.
- Clobr™ and HIHO play an important role to control pH and corrosion. Clobr is a powder product which is manually dosed. HIHO is a liquid solution dosed by injection pump into the wash system.
Controllers
- Ym-Fab control systems monitor and control all aspects of filtration and chemical dosing.
- The addition of data logging allows continuous recording for Quality Assurance.
- Training programs are available.
Pumps and Filters
- Sand filters are “backwashed” to clean the bed either by manual or automatic control. Where possible a separate water service is used for backwash.
- Insufficient backwashing is responsible for a lot of filter problems. In many cases; backwash waste can be removed and the water used again.
- Special chemicals can be used to improve filter performance in dealing with difficult loads such as peach fluff or carrot root hairs.
- Pumps selection for all Ym-Fab systems is based on water volume and the size of the filter.
Equipment
YM-FAB Post Harvest Installations
The Ym-Fab Filtration System pictured to the right has been designed to disinfect 50,000 ltr/Hr river water used to wash fruit and vegetables. Our equipment is designed to meet customer specifications.
Features:
- Automatic backwash
- Nylate®™ disinfection with ORP control
- Full data logging
- Meet QA requirements
- Effective filtration reduces chemical consumption
With all our Ym-Fab Systems there are servicing and maintenance agreements available as required.
We provide training programs and full back up support for all staff involved with Ym-Fab systems.
Pumps and Filters
- Sand filters are "backwashed" to clean the bed either by manual or automatic control. Where possible a separate water service is used for backwash.
- Insufficient backwashing is responsible for a lot of filter problems. In many cases; backwash waste can be removed and the water used again.
- Special chemicals can be used to improve filter performance in dealing with difficult loads such as peach fluff or carrot root hairs.
- Pumps selection for all YM-FAB systems is based on water volume and the size of the filter.
Probes
Product Ordering Code: YM-PROBE - ORP Probe
Also available: pH, temperature and conductivity probes.
Controllers
Monitor and Data Log pH, Temp, Chlorine, T.D.S in Produce Wash Systems and Cooling Towers.
Features:
- Incorporates High/Low Alarm
- Monitors Bromine/Chlorine
- Control pH and disinfectant levels.
- Eliminate overdosing and chemical wastage.
Our new CO-10000 controllers can be maintained by Ym-Fab personnel off site. This service includes downloading of reports and graphs of performance as required.
Feeders
- BF 12
- BF 18 Feeders
Features:
These feeders are designed as erosion feeders for Nylate, Trichlor and Activ 8.
These feeders are essentially low pressure units to be operated below 250 kpa and may require a pressure regulating valve on the inlet side. No feeder should ever be restricted on the discharge side.
Sand Filters
A full range of Filters are available.
Pump selection for all Ym-Fab systems is based on water volume and the size of the filter.
Features:
Sand filters are “backwashed” to clean the bed either by manual or automatic control. Where possible a separate water service is used for backwash.
Insufficient backwashing is responsible for a lot of filter problems. In many cases; backwash waste can be removed and the water used again.
Special chemicals can be used to improve filter performance in dealing with difficult loads such as peach fluff or carrot root hairs.
Test Strips
Order Code:
Test for NYLATE®™ levels - Nyl-tes5
Test for ACTIV 8® levels - Activtest
Features:
Activ 8® test strip range: 0 - 200 ppm
Nylate®™ Test Strips
50 Strips per bottle
- Test for bromine, pH and alkalinity
- Test range: 0–10 ppm
Activ 8® Test Strips
100 Strips per bottle
- High Range Chlorine papers
- # Test range: 0-250ppm
Other Test Strips Available
Peracetic Acid, Sulfite, High pH. Please phone if you cannot see the test strip you are after.